.TITLE Ethernet Monitor Message Definitions .IDENT /V1.0/ .FACILITY/PREFIX=ETH__ ETHERMON,456 .SEVERITY WARNING BADPROTNUM "invalid octet in Ethernet protocol number" BADADDRNUM "invalid octet in Ethernet address number" MSGLEN "specified message buffer length out of range" INVFLTNUM "specified filter is undefined or out of range" INVDSPINT/FAO=1 "invalid display interval of !UL sec; not changed" FLTTBLFUL "filter table full - new filter not added" CMPETHRD "error completing Ethernet read" ADRTBLFUL "address table full - new address/name pair not added" PRTTBLFUL "protocol table full - new protocol/name pair not added" MNFTBLFUL "manufacturer table full - new code/name pair not added" QIONETACP "error queuing status query to DECnet NETACP" CMPNETACP "error completing status query to DECnet NETACP" NETACPDAT "insufficient data returned by NETACP" DISPJAMMD "screen stalled for > 7 minutes; data munched" ERRGETSYI "error issuing $GETSYI service call" CANTSTART/FAO=1 "can't start Ethernet port, devchar=!XL" BRGROUTOVF/FAO=1 "routing table overflow for bridge #!SL" NOFASTFB TOOMANYADR "too many addresses for QUERY command; command ignored" INVTRCTYP "only 1 file format qualifier may be given on TRACE" ERRQWRMBX "error queuing write to analyzer subprocess mailbox" ERRCWRMBX "error completing write to analyzer subprocess mailbox" NOGBLSEC "couldn't create address table global section" DUPIPADR/FAO=16 "!XB-!XB-!XB-!XB-!XB-!XB has same IP adr !UB.!UB.!UB.!UB as !XB-!XB-!XB-!XB-!XB-!XB" MDUPIP/FAO=23 "!XB-!XB-!XB-!XB-!XB-!XB (!AS) claims !XB-!XB-!XB-!XB-!XB-!XB has!/!_!_!_same IP adr !UB.!UB.!UB.!UB as !XB-!XB-!XB-!XB-!XB-!XB" .SEVERITY INFORMATIONAL NODECNET "can't access DECnet services" ALLFLTDEL "all defined filters deleted" FLTDEL/FAO=1 "filter #!UL deleted" FLTADDENA/FAO=1 "filter #!UL added and enabled" FLTADDDIS/FAO=1 "filter #!UL added and disabled" FLTMODENA/FAO=1 "filter #!UL modified and enabled" FLTMODDIS/FAO=1 "filter #!UL modified and disabled" UNKETHCHR/FAO=2 "unknown Ethernet port characteristic code=!XW, !AS" UNKETHCNT/FAO=3 "unknown Ethernet port counter code=!XW, !#XL" UNDDECNOD/FAO=2 "node !UW.!UW seen on Ethernet; not in DECnet database" TRACERPT/FAO=2 "post-filter: !UL bytes, !UL messages recorded to file" TRACERPT2/FAO=2 "pre-filter: !UL bytes, !UL messages received on net" TRACERPT3/FAO=1 "pre-ETHERMON: !SL messages lost before analysis" TRACERPTA/FAO=1 "pre-analyzer: !UL messages lost due to mailbox full" ANLRPT/FAO=7 "TRACE/ANALYZER PID=!XL elapsed=!%T!/!_!_!_CPU=!%T pf=!UL bio=!UL(!UL extra) dio=!UL" LOWBYTLM/FAO=2 "current BYTLM=!UL lower than recommended minimum !UL" ADRPROTOVF/FAO=8 "no room to store !XB-!XB for !XB-!XB-!XB-!XB-!XB-!XB" PNGNOTSENT "PING message was not transmitted during wait interval" NONSTDMOP/FAO=8 "!XB-!XB-!XB-!XB-!XB-!XB had non-std MOP type !XW, len=!UB" IMOPMSG/FAO=10 "!8%T !XB-!XB-!XB-!XB-!XB-!XB sent iMOP !AS msg, t=!XW ln=!SW" MOPMSG/FAO=10 "!8%T !XB-!XB-!XB-!XB-!XB-!XB sent MOP !AS msg, t=!XW ln=!SW" ASYNTRCBEG "asynchronous TRACE command started..." ASYNTRCDON "asynchronous TRACE command completed." BADAPPLE/FAO=6 "!XB-!XB-!XB-!XB-!XB-!XB sent unknown AppleTalk layer" BRGMAPOLD "bridge map is out of date - use MAP command again" FNDINETGW/FAO=6 "!XB-!XB-!XB-!XB-!XB-!XB is an Internet IP gateway" FNDMLTIPA/FAO=14 "!XB-!XB-!XB-!XB-!XB-!XB has multiple Internet IP addresses!/!_!_first is !UB.!UB.!UB.!UB, second is !UB.!UB.!UB.!UB" PROXYARP/FAO=12 "!XB-!XB-!XB-!XB-!XB-!XB is proxy-ARPing for !XB-!XB-!XB-!XB-!XB-!XB" UNKIPARP/FAO=11 "!XB-!XB-!XB-!XB-!XB-!XB sent unknown !AS pkt: prot=!XB-!XB Hlen=!UB Plen=!UB" UNKARPOPC/FAO=11 "!XB-!XB-!XB-!XB-!XB-!XB sent unknown !AS opcode: prot=!XB-!XB opc=!XB-!XB" INCBRGDAT "incomplete data used for map - use MAP command again" LOOPDONE "looping command done" BRGTMO/FAO=1 "!UL timeouts while querying bridges - use MAP command again" BRGTMO2/FAO=1 "bridge #!UL timed out" BRGPRTINF "vague remote line data obtained; bridge map unreliable" HOWTOFIX "see user's manual section 2.2 for how to install" NEWNODE/FAO=6 "new Ethernet sender !XB-!XB-!XB-!XB-!XB-!XB detected" .SEVERITY ERROR INVNODSPC "invalid network node specification" NOFILE "can't find specified LOAD file" FILOPNERR/FAO=1 "FORTRAN I/O error #!SL trying to open LOAD file" ERROPNIND "can't open specified indirect command file" TOOMANYIND "can't nest indirect command files" NOINET "can't find known Internet software to query" NOINETDST "specified destination hasn't spoken Internet yet" BADPNGADR "can't ping to a multicast address (except Broadcast)" CANTDOIEEE "this VAX can't support IEEE 802 mode" ALRDYPRMUSR "promiscuous user already active on this interface" NOASYNTRC "no asynchronous TRACE active to abort - command ignored" STRTANLZ "couldn't start TRACE/ANALYZER command" TRCBSY "couldn't start TRACE command; previous TRACE still busy" .SEVERITY FATAL PORTASNFAI "error assigning channel to Ethernet interface" ADRTBLOVF "Ethernet address buffer table overflow - PROGRAM ABORT" PROTBLOVF "Ethernet protocol buffer table overflow - PROGRAM ABORT" NOFASTSHR INCONSIST "internal inconsistency in command parser - submit PR" .END