!------------------------------------------------------------------------------ ! ! **** HSZ Events **** ! ADD EVENT "HSZ_BAD_POWER_SUPPLY_OR_FAN" - /ABBREVIATION="BADPSF" - /COUNT=1 - /INFORMATION="BA350 shelf has a bad power supply or fan" - /PRIORITY=40 - /START=0 - /TEXT="has a bad power supply or fan" ! ADD EVENT "HSZ_LAST_FAIL" - /ABBREVIATION="LFAIL" - /COUNT=1 - /INFORMATION="Last Fail message, code & data" - /PRIORITY=80 - /START=0 - /TEXT="Last fail " ! ADD EVENT "HSZ_LAST_GASP" - /ABBREVIATION="LSTGSP" - /COUNT=2 - /INFORMATION="Last Gasp message has been received from other controller" - /PRIORITY=80 - /START=0 - /TEXT="Received LAST GASP message from other controller. Fail Code:" ! ADD EVENT "HSZ_MIST_DIAG_ERR" - /ABBREVIATION="DIAGER" - /COUNT=1 - /INFORMATION="Catastrophic boot diagnostic error, check fault code on OCP " - /PRIORITY=80 - /START=0 - /TEXT="MIST Diag-err Halting" ! ADD EVENT "HSZ_OTHER_CONTROLLER_NOT_RESPONDING" - /ABBREVIATION="NORESP" - /COUNT=2 - /INFORMATION="The other controller is not responding" - /PRIORITY=80 - /START=0 - /TEXT="Other controller not responding - RESET signal asserted" ! ADD EVENT "HSZ_OTHER_CONTROLLER_RESTARTED" - /ABBREVIATION="STRTED" - /COUNT=1 - /INFORMATION="The other controller has restarted" - /PRIORITY=10 - /START=0 - /TEXT="Other controller restarted" ! ADD EVENT "HSZ_RESTART_OTHER_CONTROLLER" - /ABBREVIATION="RESCON" - /COUNT=1 - /INFORMATION="Restart command is being entered at the - /PRIORITY=40 - /START=0 - /TEXT="RESTART OTHER" ! ADD EVENT "HSZ_RESTART_REQUIRED" - /ABBREVIATION="RESREQ" - /COUNT=1 - /INFORMATION="Changed parameters require a restart to become effective" - /PRIORITY=40 - /START=0 - /TEXT="A restart of this controller will be required before all" ! ADD EVENT "HSZ_RESTART_THIS_CONTROLLER" - /ABBREVIATION="RESCON" - /COUNT=1 - /INFORMATION="Restart command is being entered at the prompt" - /PRIORITY=40 - /START=0 - /TEXT="RESTART THIS" ! ADD EVENT "HSZ_SET_CONTROLLER" - /ABBREVIATION="SETCON" - /COUNT=1 - /INFORMATION="Set controller command is being entered at the prompt" - /PRIORITY=40 - /START=0 - /TEXT="SET CONTROLLER" ! ADD EVENT "HSZ_UP" - /ABBREVIATION="HSZUP" - /COUNT=2 - /INFORMATION="The HSZ controller has booted" - /PRIORITY=10 - /START=1 - /TEXT="Copyright © Digital Equipment Corporation" ! ADD SCAN _SCAN$HSZ - /INFORMATION="HSZ Scan Profile" - /EVENT=(HSZ_BAD_POWER_SUPPLY_OR_FAN, - HSZ_CI_PATH_LOOPBACK_FAILED, - HSZ_LAST_FAIL, - HSZ_LAST_GASP, - HSZ_MIST_DIAG_ERR, - HSZ_OTHER_CONTROLLER_NOT_RESPONDING, - HSZ_OTHER_CONTROLLER_RESTARTED, - HSZ_RESTART_OTHER_CONTROLLER, - HSZ_RESTART_REQUIRED, - HSZ_RESTART_THIS_CONTROLLER, - HSZ_SET_CONTROLLER, - HSZ_UP) ! !------------------------------------------------------------------------------